Determination of the carbon isotope ratio 13C/12C of CO2 in sparkling wines: Method using isotope ratio mass spectrometry (IRMS)- Modification

Status: In force

Determination of the carbon isotope ratio 13C/12C of CO2 in sparkling wines: Method using isotope ratio mass spectrometry (IRMS)- Modification

RESOLUTION OIV-OENO 512-2014

DETERMINATION OF THE CARBON ISOTOPE RATIO 13C/12C OF IN SPARKLING WINES: METHOD USING ISOTOPE RATIO MASS SPECTROMETRY (IRMS) - MODIFICATION

THE GENERAL ASSEMBLY,

IN VIEW of Article 2 paragraph iv of the Agreement of 3 April 2001 establishing the International Organisation of Vine and Wine,

ON THE PROPOSAL of the "Methods of Analysis" Sub-Commission,

CONSIDERING the resolution Oeno 7/2005 (Method OIV-MA-AS314-03) "DETERMINATION OF THE CARBON ISOTOPE RATIO 13C/12C OF IN SPARKLING WINES: METHOD USING ISOTOPE RATIO MASS SPECTROMETRY (IRMS)" appearing in the Compendium of International Methods of Wine and Must Analysis,

DECIDES to modify the method OIV-MA-AS314-03 by changing paragraph 6: Apparatus, and sub-paragraph 7.1: sampling procedures, as follows:

To paragraph 6: Apparatus, at the end of the sub-paragraph "Continuous-flow systems (CF-IRMS)", the following will be added:

  • Gas Sampler-IRMS. A peripheral system may be used for the on-line gas preparation, isolation of and introduction of into the isotope ratio mass spectrometer.

To sub-paragraph 7.1: CO2 sampling procedures, points "d" and "e" will be added as follows:

  • d. Refrigerate the sample at 4-5 °C, before quickly transferring the liquid into a vial and sealing it with a Teflon-silicone septum cap. Then 50 L of liquid is then transferred into a 10 mL vial and analysed. If necessary, the vial should be filled with helium in order to remove the atmospheric .
  • e. After refrigerating the sample, the bottle is opened at room temperature and a sample of 200 µL of liquid is taken using a pipette and placed in suitable vials. The vials are immediately resealed then placed in an ultrasonic bath for 10 min prior to analysis.

The statistical results of the inter-laboratory test for sampling procedures 7.1.d and 7.1.e are given in ANNEX E.

To sub-paragraph 9 (Precision) some modifications are added:

9. Precision

Details on the inter-laboratory test on precision of the method are given in Annexes D and E.

To sub-paragraph 9.1 (Repeatability):

9.1. Repeatability

9.1.1 Characteristics of sampling procedures 7.1.a-c

= 0.21 ‰

r = 0.58 ‰

9.1.2. Characteristics of sampling procedures 7.1.d and 7.1.e

  = 0.21 ‰ 

r = 0.56 ‰

To sub-paragraph 9.2 (Reproducibility):

9.2. Reproducibility

9.2.1 Characteristics of sampling procedures 7.1.d and 7.1.e

= 0.68‰

R= 1.91‰

Annexes (A,B,C,D,E)

Annex E was added to the method:

ANNEX E

Statistical results of the inter-laboratory test on sparkling and gasified wines

Sampling procedures 7.1.d and 7.1.e

In accordance with method OIV-MA-AS1-09: R2000, the following parameters were defined as part of an inter-laboratory test conducted with 16 laboratories.

Year of the inter-laboratory test: 2013-2014

Number of laboratories:16

Type of samples: Sparkling and gasified wines

Number of samples: 3, as blind duplicates

Parameter measured: 13C

INDICATORS

WINE NO. 1

WINE NO. 2

WINE NO. 3

Number of laboratories

16

14

16

Number of repetitions

2

2

2

Minimum

-32.90

-33.10

-23.64

Maximum

-29.83

-30.97

-20.57

Repeatability variance sr2

0.0467

0.0118

0.0648

Inter-group variance sL2

0.43853

0,29762

0.51616

Reproducibility variance sR2

0.4852

0.3094

0.5810

Overall average

-31.42

-31.83

-22.15

Repeatability standard deviation

0.22

0.11

0.25

r limit

0.612

0.307

0.720

Reproducibility standard deviation

0.70

0.56

0.76

R limit

1.971

1.574

2.157


Wine No. 1

Wine No. 2

Wine No. 3

Z-score

Z-score

Z-score

Laboratory Code

A

B

A

B

A

B

Wine No. 1

Wine No. 2

Wine No. 3

Lab 1

-31.40

-31.69

-31.56

-31.88

-21.93

-22.12

-0.18

-0.19

0.16

Lab 2

-31.23

-31.29

-31.43

-31.41

-21.46

-22.04

0.23

-0.73

0.52

Lab 3

-32.65

-32.12

-32.15

-32.13

-23.41

-23.64

-1.39

-0.56

-1.81

Lab 4

-31.55

-31.50

-31.46

-31.66

-22.40

-22.54

-0.15

0.48

-0.42

Lab 5

-31.50

-31.30

-31.80

-31.90

-22.00

-22.30

0.03

-0.04

0.00

Lab 6

-31.46

-31.75

-31.96

-31.75

-22.39

-22.10

-0.27

-0.05

-0.13

Lab 7

-31.48

-30.66

-31.29

-29.35

-21.47

-20.57

0.50

2.71

1.48

Lab 8

-29.83

-30.17

-29.73

-31.35

-21.50

-21.96

2.04

2.31

0.55

Lab 9

-30.96

-30.90

-31.34

-31.21

-22.22

-22.27

0.70

0.99

-0.13

Lab 10

-32.34

-32.29

-32.68

-32.75

-23.25

-23.14

-1.29

-1.60

-1.37

Lab 11

-32.90

-32.70

-33.10

-33.10

-23.00

-23.50

-1.98

-2.29

-1.45

Lab 12

-31.91

-31.68

-32.22

-32.14

-22.58

-22.66

-0.54

-0.63

-0.62

Lab 13

-31.03

-31.10

-31.61

-31.68

-21.78

-21.74

0.51

0.33

0.51

Lab 14

-31.25

-30.93

-31.43

-31.54

-22.01

-22.02

0.57

0.62

0.17

Lab 15

-30.89

-30.88

-31.59

-31.47

-21.08

-21.07

0.76

0.53

1.41

Lab 16

-31.05

-30.98

-31.24

-30.97

-21.090

-21.490

0.58

1.30

1.13


Une image contenant capture d’écran, ligne, texte, Parallèle

Description générée automatiquement

Bibliography

  1. Ana I. Cabañero, Tamar San-Hipólito and Mercedes Rupérez, GasBench/isotope ratio mass spectrometry: a carbon isotope approach to detect exogenous CO2 in sparkling drinks Rapid Commun. Mass Spectrom. 2007; 21: 3323–3328.
  2. Laetitia Gaillard, Francois Guyon ⁄, Marie-Hélène Salagoïty, Bernard Médina, Authenticity of carbon dioxide bubbles in French ciders through multiflow-isotope ratio mass spectrometry measurements. Food Chemistry. 2013, 141: 2103–2107