Ethyl Acetate (GC) (Type-IV)
OIV-MA-AS315-02A Ethyl acetate
Type IV method
- Principle of the method
Ethyl acetate is determined by gas chromatography on wine distillate using an internal standard.
-
Method
- Apparatus (see chapter Volatile Acidity).
- Procedure
Prepare an internal standard solution of 4-methyl-2-pentanol, 1 g/L, in ethanol solution, 10% (v/v).
Prepare the sample solution to be determined by adding 5 mL of this internal standard solution to 50 mL of wine distillate obtained as indicated in the chapter on Alcoholic Strength.
Prepare a reference solution of ethyl acetate, 50 mg/L, in ethanol, 10% (v/v). Add 5 mL of the internal standard to 50 mL of this solution.
Analyze 2 μL of the sample solution and the reference solution using gas chromatography.
Oven temperature is 90°C and the carrier gas flow rate is 25 mL per minute.
2.3. Calculation
S = the peak area of ethyl acetate in the reference solution.
= the peak area of the ethyl acetate in the sample solution.
I = the peak area of the internal standard in the sample solution.
I = the peak area of the internal standard in the reference solution.
The concentration of ethyl acetate, expressed in milligrams per liter, is given by:
|